The raw data files are in subfolders of "Raw Data\" corresponding to the acquisition date ("month-day\").
"Measurement Parameters" contains the different gains of the lines, used in the data analysis.

The files are ascii text. The first four lines are comments, then each line corresponds to different quantities measured at the same time, separated by tabs.
The first line indicates the measured quantities for each column, with a description detailed below and in the mathematica scripts. 

Correspondence between measured quantities as described in the first line of the raw data files and as defined in the paper:
	temps= time since beginning of measurement.
	VqpcXX=voltage applied to the gate XX (left or right of QPC E/SE/S/SW/W)
	VmifiC=d"measuredVi"/d"appliedVC", with 
		MeasuredVi i=C: Measured on ohmic contact fed by I_B, i=X: Measured on ohmic contact fed by I_F going in the X region (X=E/SE/S/SW/W)
		AppliedVC Voltage applied to the injection ohmic contact in the central region
	Vdc: dc voltage applied to ohmic contact in the central region
	PSD1/2: raw noise spectral density integrated over the measurement bandwidth for the current I_B/I_F
	